Process measuring devices Impeller with analog output signals voltage (V), frequency (Hz), current (mA) and Modbus RTU


Our MiniAirPro process meters offer precise solutions for measuring flow rates in different environments and conditions. With a variety of options (up to 5, 10, 20 or 40 m/s), including different materials (plastic, INOX) and temperature ranges (up to 80, 140 or 250°C), our products are versatile and tailored to your exact requirements.

MiniAirPro micro
MiniAir Micro plastic/aluminum up to 80°C / non-aggressive gases  Flow measuring ranges: 0.6 - 20 m/s or 0.7 - 40 m/s  Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.  Operating temperature: -30 to 80ºC  Temperature measurement with accuracy of +/-0.5°C  Cable length: 2 m    Head diameter 11 x 15 mm; insertion opening 16 mm; sensor length 165 mm  Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation. The measuring head can be replaced in just a few simple steps.  MiniAir Micro steel up to 140°C / aggressive gases  Flow measuring ranges: 1.0 - 20 m/s or 1.3 - 40 m/s   Measuring accuracy: 1.5 % f.s. and 3.5 % f.s.   Operating temperature: -30 to 140ºC   Temperature measurement with accuracy of +/-0.5°C   Cable length: 2 m     Head diameter 11 x 15 mm; insertion opening 16 mm; sensor length 165 mm  The associated five-wire cable has a length of 2 m and can be exposed to temperatures between 80 and 85°C. The probe heads can be replaced if necessary.  MiniAir Micro steel up to 250°C / aggressive gases   Flow measuring ranges: 1.0 - 20 m/s or 1.3 - 40 m/s    Measuring accuracy: 1.5 % f.s. and 3.5 % f.s.    Operating temperature: -30 to 250ºC / associated evaluation box (external electronics) up to 65°C. Cable length: 2.4 m from external electronics, 1.5 m to external electronics  Head diameter 11 x 15 mm; retraction opening 16 mm; sensor length 165 mm  The associated five-wire cable from the external electronics has a length of 2.4 m and can withstand a temperature of up to 65°C. The probe heads can be replaced if necessary. 

From SFR 730.00*
MiniAirPro Mini
MiniAirPro Mini plastic/aluminum up to 80°C / non-aggressive gases Flow measuring ranges: 0.4 - 20 m/s or 0.5 - 40 m/s Output signal: 4 - 20 mA, 0 - 1 Volt, Hz according to table or Modbus RTU Measuring accuracy: 1.0 % f.s. and 1.5 % f.s. Operating temperature: -30 to 80ºC Cable length: 5 m Head diameter: 22 x 28 mm; insertion opening 35 mm; sensor length 175 mm Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation. The measuring head can be replaced in just a few simple steps. MiniAirPro Mini steel up to 140°C / aggressive gases Flow measuring ranges: 0.7 - 20 m/s or 0.8 - 40 m/s Output signal: 4 - 20 mA, 0 - 1 Volt, Hz according to table or Modbus RTU Measuring accuracy: 1.0 % f.s. and 2.0 % f.s. Operating temperature: -30 to 140ºC Head diameter: 22 x 28 mm; retraction opening 35 mm; sensor length 175 mm The associated three-wire cable has a length of 5 m and can be exposed to temperatures between 80 and 85°C. The probe heads can be replaced if necessary. MiniAirPro Mini steel up to 250°C / aggressive gases Flow measuring ranges: 1.0 - 20 m/s or 1.3 - 40 m/s Output signal: 4 - 20 mA, 0 - 1 Volt, Hz according to table or Modbus RTU Measuring accuracy: 1.0 % f.s. and 2.0 % f.s. Operating temperature: -30 to 250ºC / associated evaluation box (external electronics) up to 65°C. Cable length: 5 m from external electronics, 2.4 m to external electronics Head diameter: 22 x 28 mm; retraction opening 35 mm; sensor length 175 mm The associated three-wire cable from the external electronics has a length of 5 m and can be exposed to temperatures between 80 and 85°C. The probe heads can be replaced if necessary.

From SFR 690.00*
MiniAirPro Macro
MiniAirPro Macro plastic/aluminum up to 80°C / non-aggressive gases Flow measuring ranges: 0.2 - 20 m/s or 0.3 - 40 m/s Output signal: 4 - 20 mA, 0 - 1 Volt, Hz according to table Measuring accuracy: 1.0 % f.s. and 1.5 % f.s. Operating temperature: -30 to 80ºC Temperature measurement with accuracy of +/-0.5°C Cable length: 5 m Head diameter: 80 x 85 mm; probe length 235 mm Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation. The measuring head can be replaced in just a few simple steps. MiniAirPro Macro brass/aluminum up to 140°C / aggressive gases Flow measuring ranges: 0.2 - 20 m/s or 0.3 - 40 m/s Output signal: 4 - 20 mA, 0 - 1 Volt, Hz according to table Measuring accuracy: 1.0 % f.s. and 1.4 % f.s. Operating temperature: -30 to 140ºC Temperature measurement with accuracy of +/-0.5°C Head diameter: 80 x 85 mm; probe length 235 mm The blades can be exchanged if required.

From SFR 1,070.00*
Replacement Snap-heads
MiniAir Micro snap-on head up to 140°C / non-aggressive gases Flow measuring ranges: 0.6 - 20 m/s or 0.7 - 40 m/s Measuring accuracy: 1.0 % f.s. and 1.5 % f.s. MiniAir Mini snap-on head plastic/aluminum up to 140°C / non-aggressive gases Flow measuring ranges: 0.4 - 20 m/s or 0.5 - 40 m/s Measuring accuracy: 1.0 % f.s. and 1.5 % f.s. MiniAir Macro plastic/aluminum up to 140°C / non-aggressive gases Flow measuring ranges: 0.2 - 20 m/s or 0.3 - 40 m/s Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.The measuring heads can be exchanged in just a few simple steps.

From SFR 230.00*

ThermoAir process measuring devices for small flows with analog output signals voltage (V) and current (mA) and Modbus RTU

Our thermoelectric anemometers offer precise and reliable velocity measurements in a wide range from 0.015 to 40 m/s with an accuracy of up to 1.0 % f.s. and 1.5 % f.m. Thanks to their robust design and versatile output signals, they are ideal for a wide range of applications. Rely on our anemometers for accurate results and reliable performance.

ThermoAir-Duct Pro
Measurement of:power consumptionVolume flowtemperatureCO2Particlesincluding UV-CVerifiability according to DIN 9001: 17025Our system is suitable for every type of planteasy installation in the existing ventilation systempermanent monitoring of air quality and air consumption (instantaneous measured values: temperature, humidity, m / s, kW, kg / h, m3 / h, hPa, Pa, PM, IAQ, Co2 - counter: kWh, m3)easy maintenance / recertificationBAFA premium of up to 80% of the costsBilling according to VDI 2077 sheet 4 possibleOur advantageTSR Messtechnik offers a unique measuring system, which impresses with its ultra-modern flexibility and needs-oriented conception. An upgrade is possible at any time.The measured values ​​can be output via a handheld measuring device, LCD display or via an RS 485 interface. The stated price includes a measuring device, LCD display or the connection to the RS 485.Applications and customer benefitsPublic institutions, commercial and industrial companies:COVID-19 prevention, analysis of indoor air, checking of particles and filters.Fair air and energy consumption-based cost distribution in accordance with the guidelines for ventilation cost accounting (according to VDI 2077 sheet 4)Precise volume flow measurement: Optimization of the process air: Measurement of waste heat + use Display of energy contributions and energy efficiency -> energy savings

SFR 7,999.00*
ThermoAir-Duct
Technical Data Measuring range: Velocity (v) 0...40 m/s Temperature (T) 0...+120 °C Accuracy in air at 22 °C and 960 hPa, incl. non-linearity, hysteresis and repeatability: (v) 0.20... 40 m/s ±(0.20 m/s + 1 % f.s.) (T) in air at 22 °C, with flow ±0.5 °C Analog output 4 - 20 mA (3-wire) Supply voltage 24 V DC Current consumption <150 mA Temperature application range Sensor -40. ..+120 °C Sensor cable -40...+105 °C Transmitter 0...+60 °C Pressure application range 700...1300 hPa Humidity application range 0...95 %rh, non-condensing Storage conditions -20...+70 °C 0...95 % rh, non-condensing Material Housing aluminum Sensor stainless steel 1.4404 Electromagnetic compatibility EN 61326-1 EN 61326-2-3

SFR 799.00*
ThermoAirPro omnidirectional
ThermoAir Pro Omnidirectional 1 m/s Flow measuring ranges: 0.015 - 1 m/s  or 0.015 - 5 m/s Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.   Output signal: 0 - 1 VDC  Power supply: 9 - 26 VDC Operating temperature: 0 to 40ºC   Cable length: 2 m Head diameter: 8 mm with protective cage 110 mm, insertion opening: 9 mm, sensor length: 300 mm Measuring media: dry instruments air or inert gases Response time: 150 ms vaporized, 2 s damped External electronics in aluminum housing: 100 x 60 x 35 mm Flow angle +/- 180°

SFR 3,080.00*
ThermoAirPro directional
ThermoAir Pro Directional 1 m/s Flow measuring ranges: 0.015 - 1 m/s or 0.015 - 5 m/s Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.   Output signal: 0 - 1 VDC  Power supply: 9 - 26 VDC Operating temperature: 0 to 40ºC   Cable length: 2 m Head diameter: 8 mm, insertion opening: 9 mm, sensor length: 300 mm Measuring media: dry instrument air or inert gases Response time: 150 ms vaporized, 2 s damped External electronics in aluminum housing: 100 x 60 x 35 mm Flow angle +/- 30°

SFR 2,550.00*