Environmental Temparature
Measuring range
Vane and handle material
Product number: SW10040.3
Product information "MiniAir6 mini"
Process measuring device - voltage signal

The MiniAir6 mini made of plastic and aluminium is suitable to use it in the environment of non aggressive gas and fluids. There are two different flow measuring ranges 0,4 to 20 m/s and
0,5 to 40 m/s. With a measuring  accuracy of the flow of 1,0 % F.S. and 1,5 % o.r. is the use of a vane anemometer most exact measurement method. The probe is usable in temperatures from -10 to +80°C. You need an external input of 9 to 26 V DC for the electricity supply. The probe has an output signal of 0 to 2,0 V. It is possible to expose the MiniAir6 with a load of the external device of 10 kΩ . The cable is 5 m long.
With the following measurements the mini is our middle snap head:
head diameter 22 x 28 mm; access opening 35 mm;  probe length 175 mm
The probe should be stored in temperatures from -65 to +150°C.

Because of the snap head principle our probes are useable for a non-stop operation and the head is easily changeable.

MiniAir6 mini stainless steel 140°C
The MiniAir6 mini made of stainless steel is suitable to use it in the environment of aggressive gas and fluids. There are two different flow measuring ranges 0,7 to 20 m/s and 0,8 to 40 m/s. With a measuring  accuracy of the flow of 1,0 % F.S. and 2,0 % o.r. is the use of a vane anemometer most exact measurement method.
You can use the probe  in temperatures from -30 to +140°C. You need an external input of 9 to 26 V DC for the electricity supply. The probe has an output signal of 0 to 2,0 V. It is possible to expose the MiniAir6 with a load of the external device of 10 kΩ . The cable is 5 m long.
With the following measurements the mini is our middle snap head:
head diameter 22 x 28 mm; access opening 35 mm;  probe length 175 mm
The probe should be stored in temperatures from -65 to +150°C.

If required the head can be replaced by us.

MiniAir6 mini stainless steel 250°C
The MiniAir6 mini made of stainless steel is suitable to use it in the environment of aggressive gas and fluids. There are two different flow measuring ranges 0,7 to 20 m/s and 0,8 to 40 m/s. With a measuring  accuracy of the flow of 1,0 % F.S. and 2,0 % o.r. is the use of a vane anemometer most exact measurement method.
You can use the probe  in temperatures from -30 to +250°C and the external electronic system in temperatures up to 65°C. You need an external input of 9 to 26 V DC for the electricity supply. The probe has an output signal of 0 to 2,0 V. It is possible to expose the MiniAir6 with a load of the external device of 10 kΩ . The cable between the probe and the external electronics system is 2 m long and the cable between the external electronics system and the electricity supply is 5 m long.
With the following measurements the mini is our middle snap head:
head diameter 22 x 28 mm; access opening 35 mm;  probe length 175 mm
The probe should be stored in temperatures from -65 to +150°C.