MC 4.0 Vane Anemometer

Prices are hidden for your customer group
Touchscreen
Water protection
additional module
Product number: 4000200.2
Product information "MC 4.0 Vane Anemometer"
The MC 4.0 anemometer is suitable for determining the flow velocity, temperature and relative humidity of gaseous and liquid media.

The measurement with a vane anemometer is considered to be the most accurate of the possible measurement methods. As a further bonus, the periodic calibration of the MC 4.0 only requires the renewal of the measuring heads. This means that the device does not need to be sent in as with comparable products.

The areas of application include flow measurements, flow measurements, filter monitoring, exhaust and supply air controls, volume flow measurements and much more.

Plastic sensors can be used for non-aggressive gases or liquids. Steel sensors are suitable for use in aggressive media.
Including logger function and the option of connecting 2 sensors.
Connections:
2 Lemo Connectors & 2 USB-C connections or 4 USB-C plugs as digital version
Display 3,2" TFT-Display, optional with Touch-Funktion (resistive)
Measuring rate 2 measures / s
Power Supply Lithium-Polymer-Battery
Operating life per battery charge approx. 15 hours (4000mAh)
Housing dimensions (LxWxH)168 x 68 x 38  mm
Protection IP 67
Weight approx. 300 gramm
Operating temperature 0 to 60 °C
Humidity 0 to 99 % rH
Protection case Removable rubber case in blue, red, green and orange
Measuring media: dry instrument air or inert gases
Units of measurement: Velocitiy: m/s, km/h, ft/s, mph Pressure: Pa / kPa, mbar, mmH2O: Flow: m/s
Measuring rate: 2 measurements / sec.
Volume flow: m³/h, l/min, m³/s, cfm

MiniAirPro Mini
MiniAirPro Mini plastic/aluminum up to 80°C / non-aggressive gases Flow measuring ranges: 0.4 - 20 m/s or 0.5 - 40 m/s Output signal: 4 - 20 mA, 0 - 1 Volt, Hz according to table or Modbus RTU Measuring accuracy: 1.0 % f.s. and 1.5 % f.s. Operating temperature: -30 to 80ºC Cable length: 5 m Head diameter: 22 x 28 mm; insertion opening 35 mm; sensor length 175 mm Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation. The measuring head can be replaced in just a few simple steps. MiniAirPro Mini steel up to 140°C / aggressive gases Flow measuring ranges: 0.7 - 20 m/s or 0.8 - 40 m/s Output signal: 4 - 20 mA, 0 - 1 Volt, Hz according to table or Modbus RTU Measuring accuracy: 1.0 % f.s. and 2.0 % f.s. Operating temperature: -30 to 140ºC Head diameter: 22 x 28 mm; retraction opening 35 mm; sensor length 175 mm The associated three-wire cable has a length of 5 m and can be exposed to temperatures between 80 and 85°C. The probe heads can be replaced if necessary. MiniAirPro Mini steel up to 250°C / aggressive gases Flow measuring ranges: 1.0 - 20 m/s or 1.3 - 40 m/s Output signal: 4 - 20 mA, 0 - 1 Volt, Hz according to table or Modbus RTU Measuring accuracy: 1.0 % f.s. and 2.0 % f.s. Operating temperature: -30 to 250ºC / associated evaluation box (external electronics) up to 65°C. Cable length: 5 m from external electronics, 2.4 m to external electronics Head diameter: 22 x 28 mm; retraction opening 35 mm; sensor length 175 mm The associated three-wire cable from the external electronics has a length of 5 m and can be exposed to temperatures between 80 and 85°C. The probe heads can be replaced if necessary.

From US$690*
MiniAirPro Macro
MiniAirPro Macro plastic/aluminum up to 80°C / non-aggressive gases Flow measuring ranges: 0.2 - 20 m/s or 0.3 - 40 m/s Output signal: 4 - 20 mA, 0 - 1 Volt, Hz according to table Measuring accuracy: 1.0 % f.s. and 1.5 % f.s. Operating temperature: -30 to 80ºC Temperature measurement with accuracy of +/-0.5°C Cable length: 5 m Head diameter: 80 x 85 mm; probe length 235 mm Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation. The measuring head can be replaced in just a few simple steps. MiniAirPro Macro brass/aluminum up to 140°C / aggressive gases Flow measuring ranges: 0.2 - 20 m/s or 0.3 - 40 m/s Output signal: 4 - 20 mA, 0 - 1 Volt, Hz according to table Measuring accuracy: 1.0 % f.s. and 1.4 % f.s. Operating temperature: -30 to 140ºC Temperature measurement with accuracy of +/-0.5°C Head diameter: 80 x 85 mm; probe length 235 mm The blades can be exchanged if required.

From US$1,070*
MiniAir micro
MiniAir Micro plastic/aluminum up to 80°C / non-aggressive gases  Flow measuring ranges: 0.6 - 20 m/s or 0.7 - 40 m/s  Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.  Operating temperature: -30 to 80ºC  Temperature measurement with accuracy of +/-0.5°C  Cable length: 2 m    Head diameter 11 x 15 mm; insertion opening 16 mm; sensor length 165 mm  Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation. The measuring head can be replaced in just a few simple steps.  MiniAir Micro steel up to 140°C / aggressive gases  Flow measuring ranges: 1.0 - 20 m/s or 1.3 - 40 m/s   Measuring accuracy: 1.5 % f.s. and 3.5 % f.s.   Operating temperature: -30 to 140ºC   Temperature measurement with accuracy of +/-0.5°C   Cable length: 2 m     Head diameter 11 x 15 mm; insertion opening 16 mm; sensor length 165 mm  The associated five-wire cable has a length of 2 m and can be exposed to temperatures between 80 and 85°C. The probe heads can be replaced if necessary.  MiniAir Micro steel up to 250°C / aggressive gases   Flow measuring ranges: 1.0 - 20 m/s or 1.3 - 40 m/s    Measuring accuracy: 1.5 % f.s. and 3.5 % f.s.    Operating temperature: -30 to 250ºC / associated evaluation box (external electronics) up to 65°C. Cable length: 2.4 m from external electronics, 1.5 m to external electronics  Head diameter 11 x 15 mm; retraction opening 16 mm; sensor length 165 mm  The associated five-wire cable from the external electronics has a length of 2.4 m and can withstand a temperature of up to 65°C. The probe heads can be replaced if necessary. 

US$1,020*
Case for instruments
Case for instruments (ideal for MC 4.0 incl. probes and extension rods).Dimensions outside [W x H x D] in mm 238 x 188 x  54Dimensions inside [W x H x D] in mm 223 x 140 x  41

US$129*
MiniWater mini
MiniWater Micro plastic/aluminum up to 80°C Flow measuring ranges: 0.02 - 5 m/s or 0.03 - 10 m/s  Measuring accuracy: 2.0 % f.s. and 3.0 % f.s.  Operating temperature: -30 to 80ºC  Temperature measurement with accuracy of +/-0.5°C  Cable length: 5 m    Head diameter 22 x 28 mm; insertion opening 35 mm; sensor length 175 mm  Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation.  The measuring head can be replaced in just a few simple steps.

Variants from US$890*
US$950*
MiniWaterPro Mini
MiniWater Mini plastic/aluminum up to 80°C Flow measuring ranges: 0.04 - 5 m/s or 0.05 - 10 m/s Output signal: 4 - 20 mA, 0 - 2 Volt, Hz according to table Measuring accuracy: 2.0 % f.s. and 3.0 % f.s. Operating temperature: -30 to 80ºC Cable length: 5 m Head diameter: 22 x 28 mm; insertion opening 35 mm; sensor length 175 mm Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation. The measuring head can be replaced in just a few simple steps.

From US$690*
MiniWater micro
MiniWater Micro plastic/aluminum up to 80°C Flow measuring ranges: 0.04 - 5 m/s or 0.05 - 10 m/s  Measuring accuracy: 2.0 % f.s. and 3.5 % f.s.  Operating temperature: -30 to 80ºC  Temperature measurement with accuracy of +/-0.5°C  Cable length: 5 m    Head diameter 11 x 15 mm; insertion opening 16 mm; sensor length 165 mm  Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation.  The measuring head can be replaced in just a few simple steps.

US$1,100*
MiniAir mini
MiniAir Mini plastic/aluminum up to 80°C / non-aggressive gases  Flow measuring ranges: 0.4 - 20 m/s or 0.5 - 40 m/s  Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.  Operating temperature: -30 to 80ºC  Temperature measurement with accuracy of +/-0.5°C  Cable length: 2 m    Head diameter 22 x 28 mm; insertion opening 35 mm; probe length 175 mm  Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation.  The measuring head can be replaced in just a few simple steps.  MiniAir Mini steel up to 140°C / aggressive gases  Flow measuring ranges: 0.7 - 20 m/s or 0.8 - 40 m/s   Measuring accuracy: 1.0 % f.s. and 2.0 % f.s.   Operating temperature: -30 to 140ºC   Temperature measurement with accuracy of +/-0.5°C   Cable length: 2 m     Head diameter 22 x 28 mm; insertion opening 35 mm; sensor length 175 mm  The associated five-core cable has a length of 2 m and can be exposed to temperatures between 80 and 85°C.  The probe heads can be replaced if necessary.  MiniAir Micro steel up to 250°C / aggressive gases   Flow measuring ranges: 0.7 - 20 m/s or 0.8 - 40 m/s    Measuring accuracy: 1.0 % f.s. and 2.0 % f.s.   Operating temperature: -30 to 250ºC / associated evaluation box (external electronics) up to 65°C.  Cable length: 1.5 m from external electronics, 2.4 m to external electronics  Head diameter 22 x 28 mm; retraction opening 35 mm; sensor length 175 mm  The associated five-wire cable from the external electronics has a length of 2.4 m and can withstand a temperature of up to 65°C.

US$850*
MiniAirPro micro
MiniAir Micro plastic/aluminum up to 80°C / non-aggressive gases  Flow measuring ranges: 0.6 - 20 m/s or 0.7 - 40 m/s  Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.  Operating temperature: -30 to 80ºC  Temperature measurement with accuracy of +/-0.5°C  Cable length: 2 m    Head diameter 11 x 15 mm; insertion opening 16 mm; sensor length 165 mm  Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation. The measuring head can be replaced in just a few simple steps.  MiniAir Micro steel up to 140°C / aggressive gases  Flow measuring ranges: 1.0 - 20 m/s or 1.3 - 40 m/s   Measuring accuracy: 1.5 % f.s. and 3.5 % f.s.   Operating temperature: -30 to 140ºC   Temperature measurement with accuracy of +/-0.5°C   Cable length: 2 m     Head diameter 11 x 15 mm; insertion opening 16 mm; sensor length 165 mm  The associated five-wire cable has a length of 2 m and can be exposed to temperatures between 80 and 85°C. The probe heads can be replaced if necessary.  MiniAir Micro steel up to 250°C / aggressive gases   Flow measuring ranges: 1.0 - 20 m/s or 1.3 - 40 m/s    Measuring accuracy: 1.5 % f.s. and 3.5 % f.s.    Operating temperature: -30 to 250ºC / associated evaluation box (external electronics) up to 65°C. Cable length: 2.4 m from external electronics, 1.5 m to external electronics  Head diameter 11 x 15 mm; retraction opening 16 mm; sensor length 165 mm  The associated five-wire cable from the external electronics has a length of 2.4 m and can withstand a temperature of up to 65°C. The probe heads can be replaced if necessary. 

From US$730*
MiniWaterPro Micro
MiniWater Micro plastic/aluminum up to 80°C Flow measuring ranges: 0.04 - 5 m/s or 0.05 - 10 m/s Output signal: 4 - 20 mA, 0 - 1 Volt, Hz according to table or Modbus RTU Measuring accuracy: 2.0 % f.s. and 3.5 % f.s. Operating temperature: -30 to 80ºC Cable length: 5 m Head diameter: 11 x 15 mm; retraction opening 16 mm; sensor length 165 mm Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation. The measuring head can be replaced in just a few simple steps.

From US$730*
MiniAir macro
MiniAir Macro plastic/aluminum up to 80°C / non-aggressive gases  Flow measuring ranges: 0.2 - 20 m/s or 0.3 - 40 m/s  Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.  Operating temperature: -30 to 80ºC  Temperature measurement with accuracy of +/-0.5°C  Cable length: 2 m    Head diameter 80 x 85 mm; probe length 235 mm  Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation.  The measuring head can be replaced in just a few simple steps.  MiniAir Macro brass/ aluminum up to 140°C / aggressive gases  Flow measuring ranges: 0.2 - 20 m/s or 0.3 - 40 m/s   Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.   Operating temperature: -30 to 140ºC   Temperature measurement with accuracy of +/-0.5°C   Cable length: 2 m     Head diameter 80 x 85 mm; sensor length 235 mm  The associated five-core cable has a length of 2 m and can be exposed to temperatures between 80 and 85°C. The impeller can be replaced if necessary.

US$1,310*