Environmental technology

Welcome to our environmental instrumentation section, where innovation and precision meet the protection of our environment. Here you will find a wide range of state-of-the-art instruments specifically designed to accurately measure and monitor a variety of environmental parameters. 
Our vane anemometers, differential pressure gauges, tunnel measurement systems and meteo sensors offer the reliability and accuracy you need to successfully realize environmental projects. Discover how our technology can help you protect the environment and develop sustainable solutions.

Our stationary solutions

MiniAirPro micro
MiniAir Micro plastic/aluminum up to 80°C / non-aggressive gases  Flow measuring ranges: 0.6 - 20 m/s or 0.7 - 40 m/s  Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.  Operating temperature: -30 to 80ºC  Temperature measurement with accuracy of +/-0.5°C  Cable length: 2 m    Head diameter 11 x 15 mm; insertion opening 16 mm; sensor length 165 mm  Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation. The measuring head can be replaced in just a few simple steps.  MiniAir Micro steel up to 140°C / aggressive gases  Flow measuring ranges: 1.0 - 20 m/s or 1.3 - 40 m/s   Measuring accuracy: 1.5 % f.s. and 3.5 % f.s.   Operating temperature: -30 to 140ºC   Temperature measurement with accuracy of +/-0.5°C   Cable length: 2 m     Head diameter 11 x 15 mm; insertion opening 16 mm; sensor length 165 mm  The associated five-wire cable has a length of 2 m and can be exposed to temperatures between 80 and 85°C. The probe heads can be replaced if necessary.  MiniAir Micro steel up to 250°C / aggressive gases   Flow measuring ranges: 1.0 - 20 m/s or 1.3 - 40 m/s    Measuring accuracy: 1.5 % f.s. and 3.5 % f.s.    Operating temperature: -30 to 250ºC / associated evaluation box (external electronics) up to 65°C. Cable length: 2.4 m from external electronics, 1.5 m to external electronics  Head diameter 11 x 15 mm; retraction opening 16 mm; sensor length 165 mm  The associated five-wire cable from the external electronics has a length of 2.4 m and can withstand a temperature of up to 65°C. The probe heads can be replaced if necessary. 

No prices for category and customer group
MiniAirPro Mini
MiniAirPro Mini plastic/aluminum up to 80°C / non-aggressive gases Flow measuring ranges: 0.4 - 20 m/s or 0.5 - 40 m/s Output signal: 4 - 20 mA, 0 - 1 Volt, Hz according to table or Modbus RTU Measuring accuracy: 1.0 % f.s. and 1.5 % f.s. Operating temperature: -30 to 80ºC Cable length: 5 m Head diameter: 22 x 28 mm; insertion opening 35 mm; sensor length 175 mm Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation. The measuring head can be replaced in just a few simple steps. MiniAirPro Mini steel up to 140°C / aggressive gases Flow measuring ranges: 0.7 - 20 m/s or 0.8 - 40 m/s Output signal: 4 - 20 mA, 0 - 1 Volt, Hz according to table or Modbus RTU Measuring accuracy: 1.0 % f.s. and 2.0 % f.s. Operating temperature: -30 to 140ºC Head diameter: 22 x 28 mm; retraction opening 35 mm; sensor length 175 mm The associated three-wire cable has a length of 5 m and can be exposed to temperatures between 80 and 85°C. The probe heads can be replaced if necessary. MiniAirPro Mini steel up to 250°C / aggressive gases Flow measuring ranges: 1.0 - 20 m/s or 1.3 - 40 m/s Output signal: 4 - 20 mA, 0 - 1 Volt, Hz according to table or Modbus RTU Measuring accuracy: 1.0 % f.s. and 2.0 % f.s. Operating temperature: -30 to 250ºC / associated evaluation box (external electronics) up to 65°C. Cable length: 5 m from external electronics, 2.4 m to external electronics Head diameter: 22 x 28 mm; retraction opening 35 mm; sensor length 175 mm The associated three-wire cable from the external electronics has a length of 5 m and can be exposed to temperatures between 80 and 85°C. The probe heads can be replaced if necessary.

No prices for category and customer group
TMS 4.0 Tunnel Measurement System
Robust sensor mechanism without moving parts. Measurement in the longitudinal direction of the tunnel. Continuous fan control possible. Maintenance-free. MEASURING RANGE: Flow: -20 ... 0 ... +20 m/s (± 0.1 m/s) Temperature: -30 ... +140 °C (± 0.25 °C) Barometric pressure at the measuring point: 600 ... 1100 mbar (± 1 mbar) OUTPUTS: 4 ... 20 mA / RS-485 MODBUS / PROFIBUS / Profinet: Flow at pitot tube A incl. polarity Flow at pitot tube B incl. polarity Average value of the flow Optional: CO: 0 - 200 ppm (± 2%) Turbidity measurement: 0 - 15 units Humidity: 0 - 100 %rH (± 2%rH) NOx: 0 - 500 ppb (± 2%) Temperature, barometric pressure Status signals Optional: CO, NOx, turbidity measurement, humidity We would be happy to customize this product to your needs. Please contact us for advice: sales@tsr-ag.ch.

No prices for category and customer group

Our mobile solutions

MC 4.0 Vane Anemometer
Touchscreen: without Touchscreen | Water protection: IP 66 | additional module: Delta P module
The MC 4.0 anemometer is suitable for determining the flow velocity, temperature and relative humidity of gaseous and liquid media. The measurement with a vane anemometer is considered to be the most accurate of the possible measurement methods. As a further bonus, the periodic calibration of the MC 4.0 only requires the renewal of the measuring heads. This means that the device does not need to be sent in as with comparable products. The areas of application include flow measurements, flow measurements, filter monitoring, exhaust and supply air controls, volume flow measurements and much more.Plastic sensors can be used for non-aggressive gases or liquids. Steel sensors are suitable for use in aggressive media.Including logger function and the option of connecting 2 sensors.Connections:2 Lemo Connectors & 2 USB-C connections or 4 USB-C plugs as digital versionDisplay 3,2" TFT-Display, optional with Touch-Funktion (resistive)Measuring rate 2 measures / sPower Supply Lithium-Polymer-BatteryOperating life per battery charge approx. 15 hours (4000mAh)Housing dimensions (LxWxH)168 x 68 x 38  mmProtection IP 67Weight approx. 300 grammOperating temperature 0 to 60 °CHumidity 0 to 99 % rHProtection case Removable rubber case in blue, red, green and orangeMeasuring media: dry instrument air or inert gasesUnits of measurement: Velocitiy: m/s, km/h, ft/s, mph Pressure: Pa / kPa, mbar, mmH2O: Flow: m/sMeasuring rate: 2 measurements / sec.Volume flow: m³/h, l/min, m³/s, cfm

No prices for category and customer group
MiniAir mini
MiniAir Mini plastic/aluminum up to 80°C / non-aggressive gases  Flow measuring ranges: 0.4 - 20 m/s or 0.5 - 40 m/s  Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.  Operating temperature: -30 to 80ºC  Temperature measurement with accuracy of +/-0.5°C  Cable length: 2 m    Head diameter 22 x 28 mm; insertion opening 35 mm; probe length 175 mm  Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation.  The measuring head can be replaced in just a few simple steps.  MiniAir Mini steel up to 140°C / aggressive gases  Flow measuring ranges: 0.7 - 20 m/s or 0.8 - 40 m/s   Measuring accuracy: 1.0 % f.s. and 2.0 % f.s.   Operating temperature: -30 to 140ºC   Temperature measurement with accuracy of +/-0.5°C   Cable length: 2 m     Head diameter 22 x 28 mm; insertion opening 35 mm; sensor length 175 mm  The associated five-core cable has a length of 2 m and can be exposed to temperatures between 80 and 85°C.  The probe heads can be replaced if necessary.  MiniAir Micro steel up to 250°C / aggressive gases   Flow measuring ranges: 0.7 - 20 m/s or 0.8 - 40 m/s    Measuring accuracy: 1.0 % f.s. and 2.0 % f.s.   Operating temperature: -30 to 250ºC / associated evaluation box (external electronics) up to 65°C.  Cable length: 1.5 m from external electronics, 2.4 m to external electronics  Head diameter 22 x 28 mm; retraction opening 35 mm; sensor length 175 mm  The associated five-wire cable from the external electronics has a length of 2.4 m and can withstand a temperature of up to 65°C.

No prices for category and customer group
Case for instruments
Case for instruments (ideal for MC 4.0 incl. probes and extension rods).Dimensions outside [W x H x D] in mm 238 x 188 x  54Dimensions inside [W x H x D] in mm 223 x 140 x  41

No prices for category and customer group
Extension rod Ø 15 x 300 mm
Extension rod Ø 15 x 300 mm

No prices for category and customer group
MC 4.0 ManoAir
The ManoAir 4.0 is suitable for measuring absolute and differential pressure and is used in process, process and medical technology, in plant construction and power, gas and waterworks, in waste incineration and HVAC systems, mechanical engineering, chemical and petrochemical industries , Automotive industry.The manometer can be equipped with two pressure modules to cover different measuring ranges:Measuring range     +/-   2000 Pa, Resolution 0.1 Pa, measuring accuracy +/- 1 PaMeasuring range     +/-     20 kPa, Resolution 0.1 kPa, measuring accuracy +/- 0.05 Pa•    Selectable units of measurement for pressure: Pa / kPa, mbar, mmH2O•    Display of rate of flow in m/s per keystroke•    Mean, minimum and maximum values per keystroke•    Automatic temperature compensation of the pressure sensor•    Logger function as standardConnections:Pressure connections: push-on nipple for 3 mm int. dia. hose & 2 USB -C connectionsDisplay 3,2" TFT-Display, optional with Touch-Funktion (resistive)Measuring rate 2 measures / sPower Supply Lithium-Polymer-BatteryOperating life per battery charge approx. 15 hours (4000mAh)Housing dimensions (LxWxH)168 x 68 x 38  mmProtection IP 67Weight approx. 300 grammOperating temperature 0 to 60 °CHumidity 0 to 99 % rHProtection case Removable rubber case in blue, red, green and orange Overload capacity: 0.675 bar without ventilation,Pressure connections: push-on nipple for 3 mm int. dia. hoseMeasuring media: dry instrument air or inert gasesUnits of measurement: Pressure: Pa / kPa, mbar, mmH2O: Flow: m/sMeasuring rate: 2 measurements / sec.Working standard: Betz Micromanometer at 22ºC / 960 hPa

No prices for category and customer group