Micro-sensors 11*15mm
MiniAir micro
No prices for category and customer group
MiniAir Micro plastic/aluminum up to 80°C / non-aggressive gases
Flow measuring ranges: 0.6 - 20 m/s or 0.7 - 40 m/s
Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.
Operating temperature: -30 to 80ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 2 m
Head diameter 11 x 15 mm; insertion opening 16 mm; sensor length 165 mm
Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation. The measuring head can be replaced in just a few simple steps.
MiniAir Micro steel up to 140°C / aggressive gases
Flow measuring ranges: 1.0 - 20 m/s or 1.3 - 40 m/s
Measuring accuracy: 1.5 % f.s. and 3.5 % f.s.
Operating temperature: -30 to 140ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 2 m
Head diameter 11 x 15 mm; insertion opening 16 mm; sensor length 165 mm
The associated five-wire cable has a length of 2 m and can be exposed to temperatures between 80 and 85°C. The probe heads can be replaced if necessary.
MiniAir Micro steel up to 250°C / aggressive gases
Flow measuring ranges: 1.0 - 20 m/s or 1.3 - 40 m/s
Measuring accuracy: 1.5 % f.s. and 3.5 % f.s.
Operating temperature: -30 to 250ºC / associated evaluation box (external electronics) up to 65°C. Cable length: 2.4 m from external electronics, 1.5 m to external electronics
Head diameter 11 x 15 mm; retraction opening 16 mm; sensor length 165 mm
The associated five-wire cable from the external electronics has a length of 2.4 m and can withstand a temperature of up to 65°C. The probe heads can be replaced if necessary.
No prices for category and customer group
MiniWater micro
No prices for category and customer group
MiniWater Micro plastic/aluminum up to 80°C
Flow measuring ranges: 0.04 - 5 m/s or 0.05 - 10 m/s
Measuring accuracy: 2.0 % f.s. and 3.5 % f.s.
Operating temperature: -30 to 80ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 5 m
Head diameter 11 x 15 mm; insertion opening 16 mm; sensor length 165 mm
Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation.
The measuring head can be replaced in just a few simple steps.
No prices for category and customer group
MiniAir micro ATEX
No prices for category and customer group
MiniAir micro ATEX plastic/aluClassification II 2G EEx ia IIC T6 / I M2 EEX ia IThe MiniAir20 ATEX probe made of plastic and aluminium is suitable to use it in the environment of explosive substances. There are two different flow measuring ranges 0,6 to 20 m/s and 0,7 to 40 m/s. With a measuring accuracy of the flow of 1,0 % F.S. and 3,0 % o.r. is the use of a vane anemometer most exact measurement method. With an accuracy of +/-0,5°C this probe is able to measure temperatures from -20 to +140°C and you can use it in temperatures from -30 to +140°C.The cable is 2 m long and can be exposed to temperatures of 80 to 85°C.With the following measurements the micro is our smallest snap head:head diameter 11 x 15 mm; probe length 165 mm The probe should be stored in temperatures from -65 to +150°C.By the snap head principle the probe is useable for a non stop operation and you can easily change the head.
No prices for category and customer group
Mini-sensors 22 *28 mm
MiniAir mini
No prices for category and customer group
MiniAir Mini plastic/aluminum up to 80°C / non-aggressive gases
Flow measuring ranges: 0.4 - 20 m/s or 0.5 - 40 m/s
Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.
Operating temperature: -30 to 80ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 2 m
Head diameter 22 x 28 mm; insertion opening 35 mm; probe length 175 mm
Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation.
The measuring head can be replaced in just a few simple steps.
MiniAir Mini steel up to 140°C / aggressive gases
Flow measuring ranges: 0.7 - 20 m/s or 0.8 - 40 m/s
Measuring accuracy: 1.0 % f.s. and 2.0 % f.s.
Operating temperature: -30 to 140ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 2 m
Head diameter 22 x 28 mm; insertion opening 35 mm; sensor length 175 mm
The associated five-core cable has a length of 2 m and can be exposed to temperatures between 80 and 85°C.
The probe heads can be replaced if necessary.
MiniAir Micro steel up to 250°C / aggressive gases
Flow measuring ranges: 0.7 - 20 m/s or 0.8 - 40 m/s
Measuring accuracy: 1.0 % f.s. and 2.0 % f.s.
Operating temperature: -30 to 250ºC / associated evaluation box (external electronics) up to 65°C.
Cable length: 1.5 m from external electronics, 2.4 m to external electronics
Head diameter 22 x 28 mm; retraction opening 35 mm; sensor length 175 mm
The associated five-wire cable from the external electronics has a length of 2.4 m and can withstand a temperature of up to 65°C.
No prices for category and customer group
MiniWater mini
No prices for category and customer group
MiniWater Micro plastic/aluminum up to 80°C
Flow measuring ranges: 0.02 - 5 m/s or 0.03 - 10 m/s
Measuring accuracy: 2.0 % f.s. and 3.0 % f.s.
Operating temperature: -30 to 80ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 5 m
Head diameter 22 x 28 mm; insertion opening 35 mm; sensor length 175 mm
Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation.
The measuring head can be replaced in just a few simple steps.
No prices for category and customer group
MiniAir mini ATEX
No prices for category and customer group
MiniAir mini ATEX plastic/aluClassification II 2G EEx ia IIC T6 / I M2 EEX ia IThe mini ATEX probe made of plastic and aluminium is suitable to use it in the environment explosive substances. There are two different flow measuring ranges 0,4 to 20 m/s and 0,5 to 40 m/s. With a measuring accuracy of the flow of 1,0 % F.S. and 1,5 % o.r. is the use of a vane anemometer most exact measurement method. With an accuracy of +/-0,5°C is this probe able to measure temperatures from -20 to +140°C and you can use it in temperatures from -30 to +140°C.The cable is 2 m long and can be exposed to temperatures of 80 to 85°C.With the following measurements the mini is our middle snap head:head diameter 22 x 28 mm; probe length 175 mm The probe should be stored in temperatures from -65 to +150°C.By the snap head principle the probe is useable for a non stop operation and you can easily change the head.MiniAir mini ATEX stainless steel to 140°CClassification II 2G EEx ia IIC T6 / I M2 EEX ia IThe mini ATEX probe made of stainless steel is suitable to use it in the environment of explosive substances .There are two different flow measuring ranges 0,7 to 20 m/s and 0,8 to 40 m/s. With a measuring accuracy of the flow of 1,0 % F.S. and 2,0 % o.r. is the use of a vane anemometer most exact measurement method. With an accuracy of +/-0,5°C is this probe able to measure temperatures from -20 to +140°C and you can use it in temperatures from -30 to +140°C.The cable is 2 m long and can be exposed to temperatures of 80 to 85°C.With the following measurements the mini is our middle snap head:head diameter 22 x 28 mm; probe length 182 mm The probe should be stored in temperatures from -65 to +150°C.If required the head can be replaced by us.MiniAir mini ATEX stainless steel to 250°CClassification II 2G EEx ia IIC T6 / I M2 EEX ia IThe mini ATEX probe made of stainless steel is suitable to use it in the environment explosive substances .There are two different flow measuring ranges 0,7 to 20 m/s and 0,8 to 40 m/s. With a measuring accuracy of the flow of 1,0 % F.S. and 2,0 % o.r. is the use of a vane anemometer most exact measurement method. This probe does not have a temperature measurement. The probe is usable in temperatures from -30 to +250°C and the external electronic system in temperatures up to 65°C.The cable is 2,4 m long (1,5 m from the external electronic system) and can be exposed to a temperatures of 250°C.With the following measurements the mini is our middle snap head:head diameter 22 x 28 mm; probe length 182 mm The probe should be stored in temperatures from -65 to +250°C.The external electronic system and the cable should be stored in temperatures to max. 65°C.If required the head can be replaced by us.
No prices for category and customer group
Macro-sensors 85*80mm
MiniAir macro
No prices for category and customer group
MiniAir Macro plastic/aluminum up to 80°C / non-aggressive gases
Flow measuring ranges: 0.2 - 20 m/s or 0.3 - 40 m/s
Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.
Operating temperature: -30 to 80ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 2 m
Head diameter 80 x 85 mm; probe length 235 mm
Thanks to the renowned snap-on head principle, the sensors are suitable for continuous operation.
The measuring head can be replaced in just a few simple steps.
MiniAir Macro brass/ aluminum up to 140°C / aggressive gases
Flow measuring ranges: 0.2 - 20 m/s or 0.3 - 40 m/s
Measuring accuracy: 1.0 % f.s. and 1.5 % f.s.
Operating temperature: -30 to 140ºC
Temperature measurement with accuracy of +/-0.5°C
Cable length: 2 m
Head diameter 80 x 85 mm; sensor length 235 mm
The associated five-core cable has a length of 2 m and can be exposed to temperatures between 80 and 85°C. The impeller can be replaced if necessary.
No prices for category and customer group
MiniAir macro ATEX
No prices for category and customer group
MiniAir macro ATEX plastic/aluClassification II 2G EEx ia IIC T6 / I M2 EEX ia IThe MiniAir macro probe made of plastic and aluminium is suitable to use it in the environment of explosive/inflammatory substances. There is just one flow measuring range from 0,3 to 40 m/s. With a measuring accuracy of the flow of 1,0 % F.S. and 1,5 % o.r. is the use of a vane anemometer most exact measurement method. With an accuracy of +/-0,5°C is this probe able to measure temperatures from -20 to +140°C and you can use it in temperatures from -30 to +100°C.The cable is 2 m long and can be exposed to temperatures of 80 to 85°C.With the following measurements the macro is our biggest snap head:head diameter 85 x 80 mm; probe length 235 mm The probe should be stored in temperatures from -65 to +150°C.By the snap head principle the probe is useable for a non stop operation and you can easily change the head.MiniAir macro ATEX plastic/stainless steelClassification II 2G EEx ia IIC T6 / I M2 EEX ia IThe MiniAir macro probe made of plastic and stainless steel is suitable to use it in the environment of explosive/inflammatory substances. There is just one flow measuring range from 0,2 to 20 m/s. With a measuring accuracy of the flow of 1,0 % F.S. and 1,5 % o.r. is the use of a vane anemometer most exact measurement method. With an accuracy of +/-0,5°C is this probe able to measure temperatures from -20 to +140°C and you can use it in temperatures from -30 to +100°C.The cable is 2 m long and can be exposed to temperatures of 80 to 85°C.With the following measurements the macro is our biggest snap head:head diameter 85 x 80 mm; probe length 235 mmThe probe should be stored in temperatures from -65 to +150°C.By the snap head principle the probe is useable for a non stop operation and you can easily change the head.MiniAir macro ATEX alu/brassClassification II 2G EEx ia IIC T6 / I M2 EEX ia IThe MiniAir macro probe made of aluminium and brass is suitable to use it in the environment of explosive/inflammatory substances. There is just one flow measuring range from 0,2 to 20 m/s. With a measuring accuracy of the flow of 0,5 % F.S. and 1,5 % o.r. is the use of a vane anemometer most exact measurement method. With an accuracy of +/-0,5°C is this probe able to measure temperatures from -20 to +140°C and you can use it in temperatures from -30 to +100°C.The cable is 2 m long and can be exposed to temperatures of 80 to 85°C.With the following measurements the macro is our biggest snap head:head diameter 80 x 70 mm; probe length 235 mmThe probe should be stored in temperatures from -65 to +150°C.By the snap head principle the probe is useable for a non stop operation and you can easily change the head.
No prices for category and customer group
accessories